TECHNOLOGY INNOVATION

TSC-D245
Digital Mass Flow Controller

TSC-D245
Direct acting valves are mounted in this model which enable better response characteristics and better stability than pilot valve systems.
FEATURES
Real time monitoring and controlling
Fast response time and high accuracy
SPECIFICATIONS
model TSC-D245
flow range (N2 Equivalent) 100 ~ 400 slm
Flow Rate Control Range 2 ~ 100% of Full Scale
Accuracy < +/- 2.0% of Full Scale
Response Time < 1.5 second (10 ~ 100%), < 3 second (2 ~ 10%)
Linearity < +/- 0.2% of Full Scale
Repeatability < 0.3% of FUll Scale
Normal Operating Pressure
Maximum Operating Pressure
Valve Shut Down
Zero Stability
Temperature Coefficient
Leak Integrity
Control Valve type Normally Closed Solenoid or Normally Opened Solenoid
Seal type Elastomer (Viton, Viton-ETP, Kalres, etc.)
Digital Interface Analog 0~5 VDC or 4 ~ 20 mA, Digital RS-485
Power Supply +15~24 VDC
Operation Temperature 5 ~50 °C (Recommended temperature range : 15~35 °C)
Warm-up Time 15 min (Accuracy Guaranteed : 30 min)
Material
Pressure Insensitivity
Display type
DIMENSIONS